欢迎访问Roland ProAV中文网站 - 支持 - V-60HD - 更新 & 驱动 - V-60HD System Program ( Ver.3.10 )
AS

V-60HD System Program ( Ver.3.10 )


HOW TO KNOW THE VERSION
Before you start, check the system program version of your V-60HD.
  1. Hold down [ OUTPUT FADE ] button, and switch on the power.
    * Continue to hold down the [ OUTPUT FADE ] button until the version information appears on the display.
  2. Check the version information that appears on the display.
    Executing this update installs the following version. If the version you're using is older, then carry out the update.
    MAIN : 3.10 b000
    NPU : 1.039
* If this shows the latest version, there's no need to update your V-60HD.

UPDATE HISTORY
[ Ver.3.10 ] 2022/04
[ Functionality Improvements ]
  • Functionality was added to enable operation of JVCKENWOOD KY-PZ200, KY-PZ400 video cameras.
    For information on supported video cameras, check "V-60HD Ver.3.1 Camera Remote Control Compatibility Information."
  • Functionality has been changed so that the audio of respective inputs can be separately output to the audio output AUX buses.
  • Functionality has been changed so that the settings for applying effects to audio sent to audio output AUX buses and SDI OUT 1, 2 embedded audio outputs can be made with greater granularity.
    This is selectable from DRY, PRE FADER, and POST FADER.
[ Bug Fixes ]
The following bugs were fixed.
  • At startup, the AUDIO EMBEDDED settings fail to be updated correctly.
[ Ver.3.06 ] 2022/02
[ Functionality Improvements ]
  • With the camera control function, when PROTOCOL is set to VISCA over IP, PTZOptics, or Avonic, the camera's tally light now no longer lights up if it is selected as PST.
[ Bug Fixes ]
The following bugs were fixed.
  • SDI audio output is 8-channel even in cases when the settings for embedded audio via SDI OUT 1 and 2 are both CH1-2.
  • Other minor bugs.
[ Ver.3.05 ] JUL 2021
  • Internal processing has been improved.
    * There is no change affecting the product specification.
[ Ver.3.04 ] JUN 2021
[ Bug Fix ]
The following bug was fixed.
  • The picture is sometimes corrupt when interlaced video is input via an SDI IN 4 connector.
[ Ver.3.03 ] MAY 2021
[ Bug Fix ]
The following bug was fixed.
  • Audio sometimes fails to be input from the SDI IN connector.
[ Ver.3.02 ] JAN 2021
[ Bug Fix ]
The following bug was fixed.
  • Audio sometimes fails to be output from the SDI OUT 1 and 2 connectors.
[ Ver.3.01 ] AUG 2020
[ Bug Fix ]
The NPU has been updated to version 1.033, correcting the following problem.
  • When operating with multiple cameras connected to the LAN, camera operation sometimes becomes impossible.
[ Ver.3.01 ] JUN 2020
[ Bug Fixes ]
The following bugs were fixed.
  • The picture sometimes flickers when interlaced video is input via an SDI IN connector.
  • Audio for which the setting INPUT MUTE: ON has been made is output via SDI OUT 2 or HDMI OUT 2.
[ Ver.3.00 ] APR 2020
[ Additional Functions ]
  • Functionality was added to enable operation of video cameras that support VISCA over IP (such as Sony video cameras), PTZOptics video cameras, and Avonic video cameras.
    For information on supported video cameras, check "V-60HD Ver.3.0 Camera Remote Control Compatibility Information."
  • A function was added to send input via AUDIO INPUT 1 to 4 and 5/6 to the AUX-bus.
  • A function was added to apply effects to audio sent to the AUX-bus.
  • A function was added to enable switching off effects applied to audio sent to the AUX-bus.
  • A function was added to enable settings for SDI and HDMI Output Audio to be made independently, without dependence on the VIDEO OUTPUT ASSIGN.
  • JPEG has been added as an image file format that can be imported via USB flash drive.
  • A function was added to save still images stored in the V-60HD to a USB flash drive.
  • Commands allowing changing the values of TEST PATTERN and TEST TONE were added to the RS-232 commands.
[ Functionality Improvements ]
  • The supported formats for SDI input were expanded by adding 1080/60p, 1080/60i, 1080/30p, 1080/29.97p, 1080/25p, 1080/24p, 1080/23.98p, and 720/60p.
  • It is now possible to change the labels for STILL 1 and 2, PGM, and PVW by using MULTI-VIEW LABEL EDIT.
  • The setting unit for AUDIO DELAY was changed from "frame" to "msec."
  • The CAPTURE IMAGE function can now also capture Output Video.
  • For TEST TONE, output at 1 kHz on the L channel and at 400 Hz on the R channel is now possible.
[ Bug Fixes ]
The following bugs were fixed.
  • A green line sometimes appears at the SPLIT V-CENTER boundary.
  • The menu items for AUDIO OUTPUT are misaligned.
  • Other minor bugs.
[ Ver.2.50 ] JUL 2019
[ Additional Functions ]
  • Functionality for operating Canon video cameras has been added.
    Supported Models: iVIS GX10, XF400, XF405
  • Functionality for operating Panasonic PTZ remote cameras has been added.
    Supported Models: AW-HE120, AW-HE130, AW-HE40, AW-HE50, AW-HE60, AW-HE65, AW-HE70, AW-HR140, AW-UE150, AW-UE70
  • Preset values have been provided for AUDIO INPUT Equalizer, Compressor, and the like. Preset values can be selected for use.
    * User presets cannot be made.
  • An effect on/off Menu item (parameter) has been added to the AUDIO Equalizer.
  • PNG has been added as a file format that can be imported via USB flash drive.
  • A setting value for making the PVW (preview) video a black screen has been added to MULTI-VIEW LAYOUT.
  • A function was added to capture input video by pressing and holding the Cross-point [1] - [6] ( [PGM 1-6] / [PST 1-6] ) buttons.
  • TRANSITION TIME has been provided for AUTO SCAN.
  • Functionality has been added to enable AUX selection and operation of the [AUTO], [CUT], [DSK], [OUTPUT FADE], and [AUTO MIX] switches via GPI.
[ Functionality Improvements ]
  • Indication of "msec" (millisecond) units has been added to the delay-time setting for AUDIO DELAY.
  • Ease of operation and visibility have been improved for AUX LINKED PGM.
    Please refer to the "V-60HD Reference Manual Version 2.5 and later" for detailed information in the [ Owner's Manuals ].
  • A black screen is no longer interposed during SPLIT ON/OFF transitions when SYSTEM FORMAT is set to "progressive."
  • Functionality has been added for stopping the progression of AUTO SCAN by using the PGM [1] - [8] or PST [1] - [8] buttons when AUTO SCAN is on.
[ Bug Fixes ]
The following bugs were fixed.
  • When some bitmap images are imported, the image is inverted.
  • With some RS-232 commands, no "acknowledge" command (ACK) is returned.
  • Other minor bugs.
[ Ver.2.01 ] MAR 2019
[ Bug Fix ]
The following bug was fixed.
  • The setting to reverse the PGM and PVW positions in MULTI-VIEW fails to be applied immediately after startup.
[ Ver.2.00 ] DEC 2018
[ Additional Functions ]
Please refer to the "V-60HD Reference Manual Version 2.0 and later" for detailed information in the [ Owner's Manuals ].
  • A function for enabling operation of JVCKENWOOD PTZ Remote Camera and Camera Recorder was added.
    - PTZ : KY-PZ100
    - StudioTally : KY-PZ100, GY-HC900, GY-HM200, GY-HM250, GY-HM258, GY-HM660, GY-HM850, GY-HM890
  • Functions for extracting a small window in PinP and for adjusting the position of the picture within the small window were added.
  • A function for enabling the SPLIT CENTER separation point to be freely adjusted was added.
  • An AUDIO INPUT SOLO function was added.
  • A function enabling reversing the PGM/PVW positions in MULTI-VIEW was added.
  • A function enabling editing of the text of MULTI-VIEW labels was added.
  • A function interlinking AUX output with PGM until an AUX button is pressed was added.
  • A function enabling randomization of the AUTO SCAN sequence was added.
  • A function enabling AUTO SCAN TIME to be set individually for each channel was added.
  • Not interposing a fade to black when a memory is loaded is now possible.
[ Bug Fixes ]
The following bugs were fixed.
  • The background picture is slightly visible even when DSK KEY LEVEL is set to "0."
  • The picture sometimes flickers momentarily during transitions when MIX TYPE is NAM.
  • Other minor bugs.
[ Ver.1.11 ] MAY 2018
[ Additional Functions ]
  • TALLY (TLY) was added to the RS-232 commands.
    Please refer to the "V-60HD Reference Manual Version 1.1 and later" for detailed information in the [ Owner's Manuals ].
  • A function was added for displaying the URL of the IP address in LAN INFORMATION as a QR code(*).
    Please refer to the " V-60HD Using Smart Tally" for detailed information in the [ Owner's Manuals ].
    * "QR code" is a registered trademark of DENSO WAVE Incorporated.
[ Functionality Improvements ]
  • Video fader level was added to the RS-232 command QPL.
[ Bug Fixes ]
The following bugs were fixed.
  • A LAN connection is dropped when backed-up data is loaded from a USB flash drive.
  • Backed-up data loaded from a USB flash drive sometimes fails to be loaded correctly.
  • TALLY-connector channel information is not applied correctly during a transition.
  • The level meter shown on the MULTI-VIEW monitor fails to be displayed correctly.
  • MEMORY LOAD sometimes fails to load some settings correctly.
  • TRANSITION TYPE fails to return to its original setting when PinP is set to OFF.
  • AUTO MIXING parameters cannot be synchronized to the RCS.
  • When the VIDEO INPUT 6 assignment is changed, color adjustment and other settings fail to be applied.
  • Audio input is impossible when the EDID for VIDEO INPUT 6 is set to INTERNAL and the unit is connected to a Mac computer.
  • Other minor bugs.
[ Ver.1.10 ] MAR 2018
[ Additional Functions ]
Please refer to the "V-60HD Reference Manual Version 1.1 and later" for detailed information in the [ Owner's Manuals ].
  • Support for remote-control functionality using V-60HD RCS was added.
  • A Smart Tally function was added.
    Please refer to the " V-60HD Version 1.1 and later Using Smart Tally" for detailed information in the [ Owner's Manuals ].
  • An AUTO SCAN function was added.
  • A Panel Information command was added to the RS-232 commands. A function for sending the Panel Information command automatically was also added.
[ Bug Fixes ]
The following bugs were fixed.
  • The following problems that occurred when recalling the unit's settings from a USB flash drive were corrected.
    • Some data fails to be saved.
    • The save state of still images changes.
  • If the power is turned off within several seconds of importing a still image, the still image is sometimes not saved.
  • In rare cases, still-image importing at startup fails.
  • When "H FLIP" is set to ON for VIDEO INPUT 5 and 6 and capture is performed, the picture is captured without horizontal flipping.
  • Audio noise is sometimes heard when HDCP is switched.
  • When the unit is started with HDCP set to ON, depending on the display device, the picture sometimes fails to display correctly.
  • The phase of test-tone output from the AUDIO OUT RCA jack is inverted.
  • Immediately after startup, the MENU button indicator sometimes lights up despite the menu not being displayed.
  • The default values of RS-232 ON/OFF and BAUDRATE were changed.
  • Other minor bugs.

WHAT YOU WILL NEED TO UPDATE
  • V-60HD
  • USB flash drive
    * The USB flash drive need to be formatted on a V-60HD.

GETTING THE UPDATE FILE
Download the file named "v60hd_sys310.zip".
The downloaded file is an archive file in ZIP format. Double-click it to expand it.
When expansion is complete, the folder v60hd_sys_v310 containing the necessary data for installation appears. Inside the folder is the file V-60HD.PRG.
Also, the v60hd_npu_1039 folder contains V-60HD_NPU.BIN.

PROCEDURE FOR THE UPDATE
Creating the Update USB flash drive
  1. Copy update file V-60HD.PRG to the root directory of a USB flash drive.
  2. Copy NPU update file V-60HD_NPU.BIN to the root directory of a USB flash drive.
    * If the procedure in "How to know the version" shows that " NPU " is NPU version 1.039, copying the V-60HD_NPU.BIN file for updating NPU is not required.
Update Procedure
[ System Update ]
  1. Turn V-60HD power OFF.
  2. Connect USB flash drive to V-60HD's USB MEMORY port. Turn the power on with pressing [ PinP 1 ] + [ SPLIT ] + [ AUX/MEMORY 1 ] buttons.
    * Continue to press and hold the button until the message "SYSTEM UPDATE" appears on the display.
  3. Press the [ VALUE ] knob. The update automatically advances.
  4. When the message "COMPLETE PLEASE RESTART" appears on the display, the update has finished.
    Turn V-60HD power OFF.

    * At the time of the first startup after updating, update processing for the display is executed and so the display might go dark, but this is not a malfunction. Wait about 20 seconds for the unit to start up.

[ NPU Update ]
* When the procedure in "How to know the version" shows that " NPU " is NPU : 1.039, the procedure in [ NPU Update ] is not required.
  1. Turn V-60HD power OFF.
  2. Connect USB flash drive to V-60HD's USB MEMORY port. Turn the power on with pressing [ MIX ] + [ WIPE 2 ] + [ AUX/MEMORY 8 ] buttons.
    * Continue to press and hold the button until the message "NPU UPDATE" appears on the display.
  3. Press the [ VALUE ] knob. The update automatically advances.
  4. When the message "COMPLETE PLEASE RESTART" appears on the monitor, the update has finished.
    Turn V-60HD power OFF.

支持