V-1200HD System Program Version 1.43
This system program updates your V-1200HD to the latest version 1.43.
                                    IMPORTANT NOTE
	After updating your V-1200HD, you should also update your V-1200HDR and V-1200HD RCS.
The V-1200HD, V-1200HDR and V-1200HD RCS should have the same version.
	The V-1200HD, V-1200HDR and V-1200HD RCS should have the same version.
How to tell the version
	Please check the version of the system working on your V-1200HD before downloading the archive file.
	
	
	- Connect a monitor to the HDMI OUT MULTI-VIEW 2 connector.
The setup menu appears on the monitor connected to HDMI OUT MULTI-VIEW 2. - Press [ MENU ] to invoke the menu screen.
 - Use the [DEC] [INC] buttons to choose System, and then press the [ ENTER ] button.
The version information screen appears. 
Version history
	[ Ver.1.43 ] OCT 2019
Bug Fix
The following bug was fixed.
	
[ Ver.1.42 ] DEC 2016
Bug Fixes
The following bugs were fixed.
	
[ Ver.1.40 ] DEC 2016
Additional Function
	
	
	
Items to prepare for the update
	
	
How to download and expand the archive file
	
	
How to update
	
	
	
Bug Fix
The following bug was fixed.
- Settings sometimes fail to be saved to a preset correctly when using the memory function at the COMPOSITION screen.
 
[ Ver.1.42 ] DEC 2016
Bug Fixes
The following bugs were fixed.
- Unintended video output occurs when the XI-SDI and XI-DVI are changed.
 - The image quality of SDI Output 5 and 6 3G-SDI Level B output has been improved.
 
[ Ver.1.40 ] DEC 2016
Additional Function
- Available for XI-DVI.
 
	[ Ver.1.32 ] SEP 2016
Additional Function
	
The following bugs were fixed.
	
[ Ver.1.30 ] JUL 2016
Additional Function
	
The following bug was fixed.
	
[ Ver.1.20 ] APR 2016
Additional Functions
	
	
[ Ver.1.15 ]
Additional Functions
	
	Additional Function
- Available for XI-DANTE.
 
The following bugs were fixed.
- Several samples were out of sync between audio channels.
 - In AUDIO PATCHBAY on the V-1200HDR, different channels could not be selected on dual monitors.
 - Changing FRAME RATE using PROCESSOR SETUP resulted in the display colors of INPUT HDMI 3/4 for MULTI-VIEW 2 failing to be reproduced correctly.
 - Inputting a 480i DVI signal to HDMI 3/4 disrupted the screen's aspect ratio.
 
[ Ver.1.30 ] JUL 2016
Additional Function
- Available for XI-SDI ( SDI EXPANSION INTERFACE ).
 
The following bug was fixed.
- V-1200HD HDMI OUT MULTI-VIEW 1 was not compatible with some of HDMI monitors.
 
[ Ver.1.20 ] APR 2016
Additional Functions
- A STILL MEMORY function has been provided.
The following functions can be used.
- Still-image loading
 - Output-video freeze and capture
 
 - RS-232C control is supported.
 
[ Ver.1.15 ]
Additional Functions
- 4:4:4 Process
 - Composition Effects
 - Audio Mixing
 - V-1200HD RCS
 
Items to prepare for the update
	Following items are required to perform the update.
	
	- V-1200HD itself
 - PC to write the updater to the USB Flash Memory
 - USB Flash Memory ( Roland's M-UF2G is recommended )
* Memory already formatted as FAT32 using a computer
* If the V-1200HD does not recognize the USB flash memory, try using a different USB memory. 
How to download and expand the archive file
	Download the file named "v1200hd_sys132.zip".
After expansion, v1200hd_sys_110 and v1200hd_sys_132 folders containing the data necessary for installation appear, with the file V-1200HD.PRG inside each.
	After expansion, v1200hd_sys_110 and v1200hd_sys_132 folders containing the data necessary for installation appear, with the file V-1200HD.PRG inside each.
How to update
	Please install the system program "V-1200HD.PRG" to the V-1200HD by following the process below.
Important notice: Never turn the V-1200HD off during the update process, or V-1200HD won't reboot correctly any more.
* The update procedure differs depending on the version currently in use.
	
If Using Ver.1.08
	
If Using Ver.1.10 / Ver.1.15 / Ver.1.20 / Ver.1.30
	
	
	
[ Update to Ver.1.10 ]
	
[ Update to Ver.1.32 ]
	
	Important notice: Never turn the V-1200HD off during the update process, or V-1200HD won't reboot correctly any more.
* The update procedure differs depending on the version currently in use.
If Using Ver.1.08
	Step 1: Run procedure [ Update to Ver.1.10 ]
Step 2: Run procedure [ Update to Ver.1.32 ]
	Step 2: Run procedure [ Update to Ver.1.32 ]
If Using Ver.1.10 / Ver.1.15 / Ver.1.20 / Ver.1.30
	Step 1: Run procedure [ Update to Ver.1.32 ]
	[ Update to Ver.1.10 ]
- Connect a monitor to the HDMI OUT MULTI-VIEW 2 connector.
 - Copy the update-use file ( V-1200HD.PRG ) inside the v1200hd_sys_110 folder to the root directory of the USB Flash Memory.
 - Turn the power on with pressing [ ENTER ] and [ INC ] buttons.
When the message "Press ENTER to execute." is displayed, the V-1200HD has entered the Update Mode.
* It takes about one minute for this process. - Connect the USB flash memory to the USB port on the front panel.
Wait about 30 seconds for the USB flash memory to be securely recognized. - Press [ ENTER ] button to start the update process.
* The update process takes 30 minutes to finish. Be sure never to switch off the power before the operation finishes.
* The indication shown on the display might stay unchanged for a long interval, but the update remains in progress.
* If the message "ERROR_END" appears on the display, follow the sequence shown below to interrupt the update, then carry out the update again from "Step 3."
1. Turn off the power to the V-1200HD.
2. Detach the USB flash memory. - When the message "Complete" is displayed, the operation has finished. (You will take about 30 minute to update.)
 - Detach the USB flash memory.
 - (After detaching the USB flash memory) Again hold down the [ ENTER ] button and the [ INC ] button and turn on the power.
Wait for the message "Connect USB memory and press ENTER to execute." to appear on the monitor (time required: approx. 1 minute).
* Do not press the [ ENTER ] button. - Without performing any operation, turn off the power to the V-1200HD.
 
[ Update to Ver.1.32 ]
- Connect a monitor to the HDMI OUT MULTI-VIEW 2 connector.
 - Copy the update-use file ( V-1200HD.PRG ) inside the v1200hd_sys_132 folder to the root directory of the USB Flash Memory.
 - Turn the power on with pressing [ ENTER ] and [ INC ] buttons.
When the message "Connect USB memory and press ENTER to execute." is displayed, the V-1200HD has entered the Update Mode.
* It takes about one minute for this process. - Connect the USB flash memory to the USB port on the front panel.
Wait about 30 seconds for the USB flash memory to be securely recognized. - Press [ ENTER ] button to start the update process.
* The update process takes 30 minutes to finish. Be sure never to switch off the power before the operation finishes.
* The indication shown on the display might stay unchanged for a long interval, but the update remains in progress.
* If the message "ERROR_END" appears on the display, follow the sequence shown below to interrupt the update, then carry out the update again from "Step 3."
1. Turn off the power to the V-1200HD.
2. Detach the USB flash memory. - When the message "Complete" is displayed, the operation has finished. (You will take about 30 minute to update.)
 - Detach the USB flash memory.
 - (After detaching the USB flash memory) Again hold down the [ ENTER ] button and the [ INC ] button and turn on the power.
Wait for the message "Connect USB memory and press ENTER to execute." to appear on the monitor (time required: approx. 1 minute).
* Do not press the [ ENTER ] button. - Without performing any operation, turn off the power to the V-1200HD.
 - Please verify the version number "1.30" with the procedure described in "How to tell the version" part of this document.